Home Inverter/UPS systems convert 12V or 24V DC battery power into 230V AC mains electricity. A typical 12V 150Ah battery holds 1.8 kWh of nominal energy (usable ~0.9 kWh on lead-acid at 50% DoD). Running 350W of essential load provides 2.5 to 3.0 hours of continuous backup.
A typical Inverter & Home UPS System is rated around 200–2500 W — that is its power draw, the speed at which it consumes electricity. What lands on your bill is energy: power × time, measured in kilowatt-hours (kWh).
A typical unit works out to about 1.75 kWh per day. This page turns your appliance’s wattage and daily run-time into that kWh number — and shows what it costs you every month.
A 12V 200Ah battery contains: (12 × 200) ÷ 1,000 = 2.4 kWh total energy. At 50% safe Depth of Discharge: 2.4 × 0.50 = 1.20 kWh usable storage.
Single 12V 200Ah: 2.4 kWh. Dual 24V 200Ah: 4.8 kWh total nominal capacity.
Tubular Lead-Acid: 50% DoD (1.2 kWh usable). Lithium LiFePO4: 90% DoD (2.16 kWh usable).
Real AC delivered = Usable kWh × 0.85 inverter efficiency factor.
| Appliance Type / Model | Typical Wattage (W) | Operational Notes & Estimated kWh |
|---|---|---|
| 12V 100Ah Lead-Acid Battery | 1.20 kWh (0.60 kWh usable) | Powers 300W load for ~1.7 hours |
| 12V 150Ah Tubular Battery | 1.80 kWh (0.90 kWh usable) | Powers 300W load for ~2.5 hours |
| 12V 200Ah Deep Cycle Tubular | 2.40 kWh (1.20 kWh usable) | Powers 300W load for ~3.4 hours |
| 24V 200Ah Dual Battery Bank | 4.80 kWh (2.40 kWh usable) | Powers 500W load for ~4.1 hours |
| Usage Scenario | Daily Usage | Monthly Energy (kWh) | Est. Monthly Cost (US Avg) |
|---|---|---|---|
| Occasional 2-Hour Outage (300W load) | 2 hours/day | 18 kWh | $2.92 |
| Daily 4-Hour Backup (350W load) | 4 hours/day | 42 kWh | $6.80 |
| Inverter Standby Idle Consumption | 24 hours/day | 18 kWh (idle loss) | $2.92 |
| Full Battery Recharging Cycle | 1.5 kWh/charge | 45 kWh | $7.29 |
A standard 12V 150Ah battery stores 1.80 kWh of energy. A 12V 200Ah battery stores 2.40 kWh. Safe usable storage is approximately 50% for lead-acid and 85-90% for lithium.
Yes. Inverters incur 15% to 20% electrical loss during AC-to-DC charging and DC-to-AC discharging, plus continuous idle standby power draw (15W–30W).
A typical 12V 150Ah battery bank (2 batteries) stores 3.6 kWh nominal (12 × 150 × 2 ÷ 1000), with about 1.8 kWh usable at 50% depth of discharge for lead-acid. That runs lights, fans, and a TV for 4–6 hours.
The inverter itself uses a small idle current (20–50W) whether loaded or not — about 0.5–1.2 kWh/day just being on. But it only converts what your appliances draw; a 2kVA inverter running a 300W load consumes ~300W plus ~30W of conversion losses.
Divide usable battery kWh by your load in kW. A 1.8 kWh usable bank running 400W of loads lasts about 4.5 hours (1.8 ÷ 0.4). Halve the load and you roughly double the backup time.
To convert kW to kWh, simply multiply the power in kilowatts (kW) by the operating time in hours: Energy (kWh) = Power (kW) × Time (hours).
Instant bidirectional power and energy conversion with animated power flow and real-time cost breakdown.
Calculate daily, monthly, and yearly electricity expenses based on equipment wattage and your regional electric tariff.
Add all devices in your home or facility to get a full energy budget breakdown and cost distribution.
Estimate the clean energy generation and monetary savings from your rooftop or commercial solar system.
Calculate the total kWh, charge time, and charging cost to recharge your electric vehicle battery.
Direct conversion between all common electrical and thermodynamic units with full mathematical precision.
Founder & Lead Renewable Energy Specialist
Abdul Rehman is a Renewable Energy Consultant and Solar Systems Specialist. He built kwtokwh.com to provide transparent, accessible calculation tools that help homeowners, electricians, and facility engineers accurately convert electrical power (kW) into billed energy consumption (kWh) calibrated against NIST and IEC metrology standards.